๐Ÿ”ฅOSHA-Compliant Fire Escape Route Maps

Fire Escape Route Maps & Planning Generator

Create professional fire escape route maps that meet OSHA and NFPA requirements. Upload your floor plan or hand-drawn sketch and get a compliant fire escape route diagram in seconds.

30 secSketch to Map
100%OSHA Compliant
1 FreeFile + 5 Regen

No design skills needed. Hand-drawn sketches welcome.

3 Simple Steps:
1Upload Floor Plan
โ†’
2Select State & Industry
โ†’
3Get Your Map

Free Fire Escape Route Map Generator

Upload your hand sketch or floor plan. Get a professional fire escape route map instantly.

๐Ÿ“Š 5 Free Regenerations Left

Create Your Fire Escape Route Evacuation Map

๐Ÿ“ท
Clear ImageUse a clean, high-quality scan or photo
โ†”๏ธ
Correct OrientationImage should be right-side up, not rotated or sideways
๐Ÿ”
No ZoomCapture the entire floor plan, avoid zooming in on sections
๐Ÿ’ก
Good LightingThe clearer and less blurry, the better results
FREE ACCOUNT

Create Your Free Account

Get 1 free file upload with 5 regenerations - completely free

โœ“1 FREE file upload + 5 regenerations
โœ“Instant AI-powered generation
โœ“100% OSHA & NFPA compliant
โœ“Print-ready PDF downloads
โœ“No credit card required
Create Free Accountโ†’
๐Ÿ”’Trusted by 500+ businesses
๐Ÿ”’Your files are private: never shared, stored temporarily, deleted automatically.

Compliance Options

๐Ÿ”ฅ NEWโœจ

Customize Your Map

Add special requests for your safety map - tell our AI exactly what you need!

  • ๐ŸŽฏAdd specific details like "Mark fire extinguisher near kitchen"
  • ๐Ÿ“Request specific zones: "Highlight assembly point in parking lot"
  • ๐ŸฅAdd safety equipment: "Include AED location near reception"
0/2000

Quick Add:

What is a Fire Escape Route?

Understanding the fundamentals of fire escape route planning and compliance

๐Ÿ—บ๏ธ

Fire Escape Route Maps

Fire escape route maps are visual representations of your facility's escape paths. These maps show primary and secondary routes, exit locations, fire extinguisher positions, assembly points, and "You Are Here" markers. Professional fire escape route maps are essential for compliance and must be posted at strategic locations throughout your building.

Generate Your Fire Escape Route Map โ†’
โšก

Why Routes Must Be Pre-Planned

During a fire, smoke reduces visibility and panic impairs decision-making. Pre-planned fire escape routes eliminate the need to think during an emergency. Regular drills ensure muscle memory takes over, guiding occupants to safety even when visual cues are obscured. Routes should be practiced quarterly at minimum.

OSHA Requirements for Fire Escape Routes

Federal regulations that govern fire escape route design and maintenance

29 CFR 1910.36

Design & Construction

  • โœ“ Fire escape routes must be permanent parts of the workplace
  • โœ“ Minimum width of 28 inches at any point along the route
  • โœ“ Ceilings must be at least 7 feet 6 inches high
  • โœ“ Routes must be free of decorations and obstructions
  • โœ“ Must lead directly outside or to an open space with access outside
29 CFR 1910.37

Maintenance & Operations

  • โœ“ Fire escape routes must be kept unobstructed at all times
  • โœ“ Exit doors must be unlocked from the inside during work hours
  • โœ“ Exit doors must swing in the direction of travel (50+ occupants)
  • โœ“ Emergency lighting with 90-minute battery backup required
  • โœ“ Illuminated exit signs visible from 100 feet minimum
29 CFR 1910.38

Emergency Action Plans

  • โœ“ Written fire escape routes must be documented
  • โœ“ Employees must be trained on escape procedures
  • โœ“ Alarm systems for route activation required
  • โœ“ Designated assembly points must be identified
  • โœ“ Employee accountability procedures required
๐Ÿ“‹

Our fire escape route generator automatically incorporates OSHA requirements. Learn more about egress map requirements and OSHA evacuation map standards.

How to Plan Fire Escape Routes

Step-by-step guidance for effective fire escape route planning

01

Assess Your Floor Plan

Start by mapping all rooms, corridors, and existing exits. Identify the locations of fire barriers, stairwells, and areas where occupants typically gather. Our AI does this automatically when you upload your floor plan or sketch.

02

Identify Primary & Secondary Routes

Establish at least two fire escape routes from every occupied space. Primary routes should follow the shortest safe path to an exit. Secondary routes provide alternatives if primary routes are blocked by fire or smoke.

03

Calculate Travel Distances

Verify that all fire escape routes meet maximum travel distance requirements. Sprinklered buildings allow longer distances (200-250 ft) than non-sprinklered (150-200 ft). High-hazard areas have stricter limits (75-100 ft).

04

Position Safety Equipment

Place fire extinguishers, pull stations, and emergency lighting along fire escape routes. Extinguishers should be within 75 feet of travel, and emergency lighting must illuminate the entire path.

05

Designate Assembly Points

Establish outdoor assembly areas at least 50 feet from the building and away from fire department operations. Assembly points should accommodate all occupants and allow for headcount accountability.

06

Document & Train

Create professional fire escape route maps and post them at strategic locations. Train all employees on routes and conduct regular drills. Update maps whenever building layout changes.

Fire Escape Route Signage Requirements

OSHA and NFPA standards for exit signs and route marking

๐Ÿšจ

EXIT Sign Specifications

EXIT signs must have letters at least 6 inches high with 3/4 inch stroke width. Signs must be illuminated with a minimum of 5 foot-candles and remain visible from any point along the fire escape route. Red or green lettering on contrasting background required.

๐Ÿ’ก

Emergency Lighting

Fire escape routes require emergency lighting that provides at least 1 foot-candle of illumination at floor level. Lighting must activate automatically during power failure and maintain illumination for minimum 90 minutes.

โžก๏ธ

Directional Signs

Where the path to the nearest exit is not immediately apparent, directional signs with arrows must indicate the direction to the fire escape route. Signs must be placed at corridors, lobbies, and any decision points along the route.

๐ŸŒ™

Photoluminescent Markings

High-rise buildings require photoluminescent markings on stairwell handrails, stair treads, and egress path markings. These glow-in-the-dark markers remain visible even when emergency lighting fails or smoke obscures powered signs.

Common Mistakes in Fire Escape Route Planning

Avoid these critical errors that can compromise safety and compliance

โŒ

Exits Too Close Together

When fire escape route exits are placed too close together, a single fire can block both. NFPA requires exits to be separated by at least half the diagonal distance of the space served.

Solution:Position exits on opposite sides of the building or at maximum practical distance apart.
โŒ

Blocked or Obstructed Routes

Storage, equipment, or furniture blocking fire escape routes is the most cited OSHA violation. Even temporary obstructions during business hours create life-threatening situations.

Solution:Conduct weekly route inspections and enforce strict no-obstruction policies with clear floor markings.
โŒ

Outdated Route Maps

Fire escape route maps that don't reflect current building layout cause confusion during emergencies. Renovations, furniture rearrangements, and new hazards make old maps dangerous.

Solution:Update maps immediately after any changes and review annually. Use our generator for quick updates.
โŒ

No ADA Considerations

Failing to plan fire escape routes for occupants with disabilities violates ADA requirements. Standard routes may not work for wheelchair users or those with mobility impairments.

Solution:Include areas of refuge, accessible routes, and evacuation chair locations in your planning.
โŒ

Inadequate Training

Having fire escape routes without training employees to use them defeats the purpose. Untrained occupants won't remember routes during the panic of an actual emergency.

Solution:Conduct quarterly fire drills and train new employees within their first week.
โŒ

Dead-End Corridors

Dead-end corridors exceeding 20 feet (50 feet if sprinklered) trap occupants with no escape if fire blocks the only exit. This is a serious code violation.

Solution:Add secondary exits or redesign layout to eliminate dead-ends. Our AI identifies these issues automatically.

Trusted by Safety Professionals

"We needed fire escape route maps for our 12-floor office building. The AI mapped all routes with stairwell assignments in minutes. Fire marshal was impressed."
Michael TorresBuilding Manager, Commercial Tower
"After our renovation, we uploaded a quick sketch and had updated fire escape route maps the same day. No waiting for expensive consultants."
Jennifer WalshFacilities Director, Healthcare Clinic
"The AI identified a dead-end corridor issue we'd overlooked for years. The fire escape route map update helped us avoid a citation."
David KimSafety Manager, Manufacturing Facility

Ready to Create Your Fire Escape Route Map?

Upload your hand sketch or floor plan and get a professional fire escape route map in seconds. Register for 1 free file upload with 5 regenerations.